Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
/VM/station wiki
Search
Search
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Guide to power
(section)
Page
Discussion
English
Read
Edit
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
View history
General
What links here
Related changes
Special pages
Page information
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==== Dual-Wiring: The Best of Both Worlds ==== There is another, less used option that utilizes the benefits from both wiring ideologies while mitigating the risk: dual-wire the solar arrays both to the Solar SMESs and directly into the grid at the same time. Initially, the Engineer would want to charge the SMESs enough to where they could give an adequate supply of power. Then, if the Engineer is skilled enough at wiring, both the SMES and the solar arrays can be wired to the grid at the same time. Since the station only draws about 150 kW, but the solars wired to grid produce 180 kW, there's a spare 30 kW to split between the Solar SMESs for recharging. Setting all four Solar SMESs to charge at 6 kW is feasible (reduced from 7.5 kW to account for broken solar panels). The output setting on the SMES can be any value so long as the station draws full power from the solars wired directly. This effectively makes the Solar SMESs a backup power source. The drawbacks though are that the Solar SMES input levels should not be put higher than 6 kW since a Solar SMES located at an array going through the night cycle will attempt to draw power from a Solar SMES higher upstream in the [[#power queue]], cannibalizing the power from that SMES. Also, the 2 conventional Backup SMESs can't be charged for the same reason of the power queue. However, since the 4 Solar SMESs act as backups, this trade-off is in favor of the dual-wiring of the solars. The Solar SMESs will still be prone to power sinks, but since the solars are wired directly to the grid it doesn't matter much. The drawback that all solars must be wired directly to the grid to prevent severe fluctuation. The same is not true of the SMES-side of this set-up. Each SMES acts like an independent backup, so any undesired SMESs don't have to be set, making the system semi-modular. '''Pros:''' acts primary and backup power source, deters sabotage, resistant to power sinks, semi-modular, resistant to brownouts '''Cons:''' severe fluctuations if incompletely implemented, requires insulated gloves, often incorrectly wired, requires initial charging and follow up on the SMESs before implementation
Summary:
Please note that all contributions to /VM/station wiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
/VM/station wiki:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Toggle limited content width